This Hikari 12 volt 50 watt lamp is an exact replacement for Wild, Leitz and Leica 384-643 microscope bulbs."
This Hikari MR-11 FTE Cover 1462, MR-8053PC bulb with ANSI code FTE uses 35 watts and 12 volts. It has a GZ4 base, and an average rated life of 2500 hours. It has a MR11 lamp shape, and is a halogen bulb.
FTE bulb. Applications: stage, studio, medical equipment.
"Halogen double-envelope capsule bulb with inside frost. JDD130V/100W, 100T10.
"The 100Q/CL/MC is a 100 watt, T4 halogen with a rated life of 2000 hours. Features include: bright, crisp light; a UV-filter halogen capsule; and uniform light output.
The 150P25/2SB clear, silvered bowl incandescent lamp is used as a surgical lamp in older style operating rooms.
The lamp optics produce a medium angle spot. Features include a C5 filament, 2200 initial lumens and a 200 hour rated life.
Cross reference brand part numbers: GE 19334, Osram Sylvania 15014, Ushio 8000071. This bulb is also known as: 45704091, 003621.
"This Hikari J 130V 150W 78MM 1125, J-1013 bulb uses 150 watts and 130 volts. It has a R7S base, and an average rated life of 2000 hours. It has a T3 lamp shape, and is a halogen bulb.
150T3Q/CL BULB. J-Type 78mm short. Cross reference: SATCO S3135.
"This Hikari JDD-7517F bulb uses 250 watts and 130 volts. It has a E26 medium base, and an average rated life of 2000 hours. It has a T10 lamp shape, and is a halogen bulb.
This 120 volt, 250 watt halogen lamp has a medium base.
"Cross Reference: Industry Standard (JC12V-35W); Ushio (1000825).
This Hikari JD 130V 400W MC E11 1233, JD-7031 bulb uses 400 watts and 130 volts. It has a E11 mini candelabra base, and an average rated life of 2000 hours. It has a T4 lamp shape, and is a halogen bulb.
Cross Reference: Industry (Q400T4/CL, JCV120V-400W), Ushio (1000976), GE (43707).
"This Hikari JCD 130V 50W GY6.35 1323, JCD-6013 bulb uses 50 watts and 130 volts. It has a GY6.35 base, and an average rated life of 1300 hours. It has a T4 lamp shape, and is a halogen bulb.
50T4Q/130 JCD 130V 50W bulb. Cross reference: Westinghouse 04417.
"ANSI EHT. For frosted bulb use ESM. Cross Reference: Industry (JCV120V- 250WGSN), Ushio (1000294), Osram Sylvania (58762), GE (43699)
Possible substitute: Q250CL/MC.
"This Hikari JD 130V 250W MC E11 1231, JD-7023 bulb with ANSI code EHT/131 uses 250 watts and 130 volts. It has a E11 mini candelabra base, and an average rated life of 2000 hours. It has a T4 lamp shape, and is a halogen bulb.
EHT bulb. Cross Reference: Industry (JCV120V-250WGSN), Ushio (1000991)
"This Hikari MR-16 EYJ 1456, MR-8047C bulb with ANSI code EYJ uses 75 watts and 12 volts. It has a GX5.3 base, and an average rated life of 4000 hours. It has a MR16 lamp shape, and is a halogen bulb.
EYJ bulb. Cross Reference: Ushio (1000454).
"FSV bulb. Application notes: narrow flood beam spread. Cross reference: Ushio (1000611), Q20MR11/NFL/BA.
"This Hikari MR-11 FTH Cover 1470, MR-8065PC bulb with ANSI code FTH uses 35 watts and 12 volts. It has a GZ4 base, and an average rated life of 2500 hours. It has a MR11 lamp shape, and is a halogen bulb.
FTH bulb. Applications: stage, studio, display lighting.
"G15T8 UV GERMICIDAL bulb replacement lamp. is 15 watts and 436mm in length. See document below for a complete list of equipment brands and models using the G15T8 lamp.
G40T10 UV GERMICIDAL bulb replacement. Ushio 3000315, GE 15876.
"The Higuchi LU150/M high pressure sodium lamp produces 16,000 initial lumens and offers universal operating position options.
"The Higuichi LU250 high pressure sodium lamp produces 28,500 lumens and is designed for universal operating position applications.
"The Higuchi LU400 high pressure sodium lamp provides 47,500 initial lumens and offers a 24,000 hour rated life.
"The Higuchi LU70 high pressure sodium lamp provides excellent performance in a value package.
This Hikari JC G6.35 Clear Gold Pin 676, M-01096 bulb uses 180 watts and 22.7 volts. It has a G6.35 base, and an average rated life of 50 hours. It has a T4 lamp shape, and is a halogen bulb.
HIGUCHI M-01096 / BSS1089. Applications include: medical equipment.
Use this Hikari MR16 narrow flood for line voltage (120V) accent lighting applications.
Hikari BAB 20 watt 12 volt MR16 flood bulb. Applications: stage, studio, museums, display, track and cable lighting. Cross Reference: Osram Sylvania (58646, 54200), Ushio (1000000), Philips (37803-4), GE (25480).
"The EXN is a 50 watt MR16 with a 36?é?? beam flood light distribution.
EXN is used in specialty applications such as display lighting, studio and stage lighting, medical and photo enlarging equipment.
"This Hikari brand JDR-9523FP provides 120 volt operation for the ANSI EXN MR16 halogen.
Frosted front glass for diffuse illumination.
This Hikari MR-16C 24V/50W FLOOD EXN/24 bulb with ANSI code EXN/2 uses 50 watts and 24 volts. It has a GU5.3 base, and an average rated life of 2000 hours. It has a MR16 lamp shape, and is a halogen bulb.
EXN/2 bulb.
"This Hikari MR-16 FMT 1438, MR-8021C bulb with ANSI code FMT uses 35 watts and 12 volts. It has a GX5.3 base, and an average rated life of 3500 hours. It has a MR16 lamp shape, and is a halogen bulb.
FMT bulb. Cross Reference: Ushio (1000548).
"This Hikari MR-16 FNV 1436, MR-8019C bulb with ANSI code FNV uses 50 watts and 12 volts. It has a GU5.3 base, and an average rated life of 2000 hours. It has a MR16 lamp shape, and is a halogen bulb.
FNV bulb. Cross Reference: Ushio (1000589).
"This Hikari G6T5 light bulb has a lamp shape of T5 and uses 6 watts.
This Hikari G8T5 light bulb has a lamp shape of T5 and uses 8 watts.
Cross Reference: Industry (JC24V-20W, 20T3Q/CL/24V), Ushio (1000844), Osram Sylvania (58662, 64435), Westinghouse (04437).
This Topbulb JCD130V20WG8S bulb uses 20 watts and 130 volts. It has a G8 base, and an average rated life of 1500 hours. It has a T4 lamp shape, and is a halogen bulb.
JCD130V20WG8S
This Hikari JDR 120V 100W E26 Frost 40deg 1371, JDR-9059F bulb uses 100 watts and 120 volts. It has a E26 medium base, and an average rated life of 2000 hours. It has a MR16 lamp shape, and is a halogen bulb.
Cross Reference: Ushio (1001014).
"This Hikari JRM12V5WG4 bulb uses 5 watts and 12 volts. It has a G4 base, and an average rated life of 1000 hours. It has a MR11 lamp shape, and is a halogen bulb.
Beam spread: 30 degrees. Applications: fiber optics.
"This Hikari MR11 6V 5W G4 30deg 1416, JCR-8193 bulb uses 5 watts and 6 volts. It has a G4 base, and an average rated life of 1000 hours. It has a MR11 lamp shape, and is a halogen bulb.
Applications: fiber optics.
"This Hikari JC 24V 10W G4 1202, JC-5063 bulb uses 10 watts and 24 volts. It has a G4 base, and an average rated life of 2000 hours. It has a T3 lamp shape, and is a halogen bulb.
JC24V-10W BULB.
"Applications: microscope. Cross Reference: Ushio (1000857), Zeiss (38- 61-08, 91-01-54), BLV (1167).
"Applications: optical instruments, low voltage task lights. Cross Reference: Industry (JD6V-5W). Ushio (1000874).
"This Hikari O-64484FR bulb uses 75 watts and 130 volts. It has a E26 medium base, and an average rated life of 2000 hours. It has a T10 lamp shape, and is a halogen bulb.
JDD130V/75W, 75T10 bulb.
This Hikari MR11 12V 10W G4 30deg 1423, JCR-8297 bulb uses 10 watts and 12 volts. It has a GU4 base, and an average rated life of 1500 hours. It has a MR11 lamp shape, and is a halogen bulb.
JRM-12V/10W/G4. Application: retail display (UV stop).
"Use this quality Hikari (Higuchi) replacement lamp for Narva and Guerra compatible microscope lamps. See brands and models below.
This Hikari JC 12V 10W BA15S 1179, JC-4010 bulb uses 10 watts and 12 volts. It has a BA15S base, and an average rated life of 2000 hours. It has a T3 lamp shape, and is a halogen bulb.
Q10T3/CL/BA15S
"This Hikari J 130V 300W 118MM 1132, J-2023 bulb uses 300 watts and 130 volts. It has a R7S base, and an average rated life of 2000 hours. It has a T3 lamp shape, and is a halogen bulb.
Cross Reference: Industry (Q300T3/CL/130, J130V-300W), Ushio (1000726), Eiko (15166).
"This Hikari JC 12V 50W GY6.35 1197, JC-5043 bulb uses 50 watts and 12 volts. It has a GY6.35 base, and an average rated life of 2000 hours. It has a T4 lamp shape, and is a halogen bulb.
Hikari JC5043 12 volt 50 watt halogen. Cross Reference: GE (19376), Ushio (1000827).
"This Q75CL/E14 halogen JD clear European (E14) base bulb provides UV protection. For best performance do the following: make sure pins are properly seated in the socket, clean lamp with dry cloth only, and do not touch bulb to avoid shortened lamp life. Applications include portable lighting, track, wall mount, and sconce lighting.
"This Hikari JD 130V 75W E11 Base Clear 1223, JD-7007 bulb uses 75 watts and 130 volts. It has a E11 mini candelabra base, and an average rated life of 1500 hours. It has a T3 lamp shape, and is a halogen bulb.
Q75CL/MC/130V
"